Submersible Pumpsets – Openwell, Horizontal Radial Flow 5 to 15 HP (3 Phase)

PERFORMANCE CHART – OPENWELL HORIZONTAL SUBMERSIBLE PUMPSETS

Sr.
No.

Model No.
Type Motor
HP (kW) & (Max. Amp. @ H)
Pump
Size (mm)
4.2 5.0 5.8 6.7 7.5 8.3 9.2 10.0 10.8 11.7 12.5 13.3 14.2 15.0 15.8 16.7 18.3 20.0 21.7 lps
250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 1300 lpm
1 MPA-3 RF, DOL 3 (2.2)
(6.0)
50 x 50 26 34 24H 21 17 H

e

a

d

 

I

n

M

e

t

r

e

s

2 MPA-5 RF, DOL 5 (3.7)
(9.0)
50 x 50 33 32H 28 23
3 MPA-6 RF, DOL 6 (4.5)
(11.0)
50 x 50 47 41 40 38H 34 28
4 MPA-7 RF, DOL 7.5
(5.5) (13.0)
50 x 50 46 45H 40 32 21
5 MPA-10 RF, SD 10 (7.5)
(17.0)
50 x 50 48 47 45H 40 33 24
6 MPA-12 RF, SD 12.5
(9.3) (21.0)
50 x 50 52 51 50H 45 39 25
7 MPA-15 RF, SD 15
(11.0) (25.5)
50 x 50 57 56 55H 50 44 30
8 MPB-3 RF, DOL 3 (2.2)
(6.0)
65 x 65 19 18 17H 15 11
9 MPB-5 RF, DOL 5 (3.7)
(9.0)
65 x 65 25 24 23H 20 16
10 MPB-6 RF, DOL 6 (4.5)
(11.0)
65 x 65 29 28 27H 24 20
11 MPB-7 RF, DOL 7.5
(5.5) (13.0)
65 x 65 32 31 30H 27 23
12 MPB-10 RF, SD 10 (7.5)
(17.0)
65 x 65 35 34H 33 29 24
13 MPB-12 RF, SD 12.5
(9.3) (21.0)
65 x 65 40 39 38H 37 29
14 MPB-15 RF, SD 15
(11.0) (25.5)
65 x 65 55 54H 53 49 44
15 MPC-3 RF, DOL 3 (2.2)
(6.0)
80 x 80 17 16 15H 13 10
16 MPC-5 RF, DOL 5 (3.7)
(9.0)
80 x 80 20 19 18H 15 12
17 MPC-6 RF, DOL 6 (4.5)
(11.0)
80 x 80 24 23H 22 19 16
18 MPC-7 RF, DOL 7.5
(5.5) (13.0)
80 x 80 29 28 27H 24 21
19 MPC-10 RF, SD 10 (7.5)
(17.0)
80 x 80 31 30H 29 26 22
20 MPC-12 RF, SD 12.5
(9.3) (21.0)
80 x 80 36 35 34H 30 25
21 MPC-15 RF, SD 15
(11.0) (25.5)
80 x 80 42 41 40H 36 31
22 MPD-5 RF, DOL 5 (3.7)
(9.0)
100 x 100 13 14 15H 12 8
23 MPD-6 RF, DOL 6 (4.5)
(11.0)
100 x 100 16 17 18H 15 11
24 MPD-7 RF, DOL 7.5
(5.5) (13.0)
100 x 100 18 19 20H 16 11
25 MPD-10 RF, SD 10 (7.5)
(17.0)
100 x 100 22 23 24H 20 15
26 MPD-12 RF, SD 12.5
(9.3) (21.0)
100 x 100 27 28 29H 25 20
27 MPD-15 RF, SD 15
(11.0) (25.5)
100 x 100 33 34 35H 31 26
 

All Above Models Are 3-Phase,
350/440 Volts, 2820/2880 RPM, 50 Hz & 2 Poles.

Important Note : Never Test
Pumpset In Dry condition. Pure Water Must completely Be Filled In Motor &
Casing Of PUmp Before Testing, Testing Period Must Not Exceed 15 Seconds. All
Precautionary Measures As Specified In Given Manual, Must Be Adhered Carefully.

7.5 HP Submersible Pumpsets
With SD = (Delta Connection) (Double Cable) Can Also Be Made Available

  • RF = Radial Flow Pump
  • H = Duty Point Head
  • DOL = 8 (Star Connection) (Single
    Cable)
  • SD = ) (Delta Connection) (Double
    Cable)